ANSI 15 Changes 10-31-13
ANSI/APSP 15 Addenda A changes how to comply with the standard for Residential Swimming Pool and Spa Energy Efficiency requirements.
We have been informed of addenda to ANSI 15 that makes compliance a little easier. However, the changes may or may not be recognized by a Building Department as effective in the Florida Building Code (FBC). The following TWO issues represent changes:
Single Speed Pumps
For pool only systems (no auxiliary flow such as spa or sheer flow), any listed single speed pump may be selected, provided the “motor HP” is less than 1 hp. That is, the “name plate HP” multiplied by the “motor service factor”. That means the following pumps may now be permitted for use on such projects:
AquaPro Sunrunner SUNP2200U
Hayward SP2305X7EE
Hayward SP2305X7EESP
Hayward SP2607EE
Hayward SP2705X7EE
Hayward SP3007EECA
Hayward SP3205EE
Hayward SP3205X7
Sta-Rite P6E6C-204L
Sta-Rite PE52C-180L
Sta-Rite PE5C-180L
Sta-Rite PEA5D-180L
Pentair PFII-P1-3/4A
Pentair WF-2
Pentair WF-23
Pentair WFE-2
Spec Pump A91
Spec Pump A91-1
Spec Pump A91-R
Wayne Water WI90
Jandy Pro Series MHPM 0.75
Jandy Pro Series PHPM 0.75
Jandy Pro Series SWF125
The second change defines the filter sizing based only on the filtration flow, instead of the higher of filtration flow and auxiliary flow. So, the number of spa jets or an in-floor system no longer defines the filter size. However, it remains a valid recommendation to use a larger filter when there is auxiliary flow.